A 8 month female with Tetralogy of Fallot is brought to the OR for primary repair. When ordering the infusions for the case and knowing that a patient with this repair is high risk for post operative arrhythmias, you have chosen to order amiodarone. The pharmacist sends the amiodarone infusion along with the "special" tubing for its administration. Which of the following concerning this practice is true?

A. The special tubing is not needed for this patient

B. Normal PVC tubing causes adsorption of the amiodarone infusion and may lower the effective dose delivered

C. Amiodarone in normal tubing may cause fertility issues in this patient later in life

D. Amiodarone is photosensitive and needs special tubing to be shielded from light