__NOTOC__ | __NOTOC__ | ||
Concerning pediatric echocardiography, what is true concerning shortening fraction (SF) versus ejection fraction (EF)? | Concerning pediatric echocardiography, what is true concerning shortening fraction (SF) versus ejection fraction (EF)? | ||
Line 11: | Line 10: | ||
D. Shortening fraction is normally 50-70% | D. Shortening fraction is normally 50-70% | ||
<div class="mw-customtoggle-TYK_Answer" style="text-align: right; color:#0000ff">Click for Answer</div> | |||
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-TYK_Answer"> | |||
<div class="mw-collapsible- | |||
==Answer== | ==Answer== | ||
The answer is C. | The answer is C. | ||
Ejection fraction is the most commonly used ECHO parameter to measure contractility. EF has several limitations including being a load dependent measurement. The EF is practically measured by the following calculation: | Ejection fraction is the most commonly used ECHO parameter to measure contractility. EF has several limitations including being a load dependent measurement. The EF is practically measured by the following calculation: | ||
::EF = ((End diastolic volume-End systolic volume)/(End diastolic volume)) | ::EF = ((End diastolic volume-End systolic volume)/(End diastolic volume)) | ||
A normal EF is usually greater than 50-60%. | A normal EF is usually greater than 50-60%. | ||
Shortening fraction (SF) is a two dimensional equivalent of EF. When only the end diastolic (or systolic) DIAMETER is known (remember EF uses a VOLUME measurement), then shortening fraction must be used. The normal shortening fraction is usually >0.28. SF was originally used when ECHO consisted only of M-mode (one dimension). More recent advances in 2-D echocardiography have improved the accuracy of generating a 3-D value (volume and subsequent EF) from a 2-D image. However, despite these differences, there are some cardiologists and institutions who still report contractility in SF. You just need to know the normals for each and which one they are talking about. Remember, SF does not equal EF. | Shortening fraction (SF) is a two dimensional equivalent of EF. When only the end diastolic (or systolic) DIAMETER is known (remember EF uses a VOLUME measurement), then shortening fraction must be used. The normal shortening fraction is usually >0.28. SF was originally used when ECHO consisted only of M-mode (one dimension). More recent advances in 2-D echocardiography have improved the accuracy of generating a 3-D value (volume and subsequent EF) from a 2-D image. However, despite these differences, there are some cardiologists and institutions who still report contractility in SF. You just need to know the normals for each and which one they are talking about. Remember, SF does not equal EF. | ||