TYK38: Difference between revisions
Jump to navigation
Jump to search
https://pedsanesthesia.net/wikiOLD032021>JustinHamrick mNo edit summary |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
__NOTOC__ | __NOTOC__ | ||
All of the following are true concerning V/Q ratios EXCEPT: | All of the following are true concerning V/Q ratios EXCEPT: | ||
Line 10: | Line 9: | ||
D. Deadspace is represented by a V/Q value of 0.5. | D. Deadspace is represented by a V/Q value of 0.5. | ||
<div class="mw-customtoggle-TYK_Answer" style="text-align: right; color:#0000ff">Click for Answer</div> | |||
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-TYK_Answer"> | |||
<div class="mw-collapsible- | |||
==Answer== | ==Answer== | ||
The answer is D. Deadspace ventilation is represented by a value of infinity and certainly >0.5. All other choices are correct. | The answer is D. Deadspace ventilation is represented by a value of infinity and certainly >0.5. All other choices are correct. | ||
==Notes== | ==Notes== | ||
<references /> | <references /> | ||
==Keywords== | ==Keywords== | ||
</div> | </div> | ||
---- | ---- | ||
---- | ---- |
Latest revision as of 22:22, 23 January 2022
All of the following are true concerning V/Q ratios EXCEPT:
A. In an awake, spontaneously breathing patient, the normal matching of V/Q is 0.8
B. An absolute shunt has a V/Q value of 0.
C. Hypoxic pulmonary vasoconstriction (HPV) is an intrapulmonary mechanism that attempts to minimize V/Q mismatching.
D. Deadspace is represented by a V/Q value of 0.5.
Click for Answer
Answer
The answer is D. Deadspace ventilation is represented by a value of infinity and certainly >0.5. All other choices are correct.