TYK12: Difference between revisions

From PedsAnesthesiaNet
Jump to navigation Jump to search
m (1 revision imported)
No edit summary
Tags: Mobile edit Mobile web edit Advanced mobile edit
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
__NOTOC__
__NOTOC__
<div class="mw-collapsible mw-collapsed" style="width:100%">
In regards to detection of a venous air embolus, which of the following modalities is most sensitive?
In regards to detection of a venous air embolus, which of the following modalities is most sensitive?


Line 16: Line 15:


G. End-tidal carbon dioxide concentration
G. End-tidal carbon dioxide concentration
 
<div class="mw-customtoggle-TYK_Answer" style="text-align: right; color:#0000ff">Click for Answer</div>
 
<div class="mw-collapsible mw-collapsed" id="mw-customcollapsible-TYK_Answer">
 
<div class="mw-collapsible-content">  
==Answer==
==Answer==
 
The answer is B. Doppler is the most sensitive. Echo is the most specific.  All others can be used and have signs associated with VAE.
The answer is B. Doppler is the most sensitive. Echo is the most specific.  All others can be used and have signs associated with VAE.  
 
 


==Notes==
==Notes==
<references />
<references />


==Keywords==
==Keywords==
:


</div>
</div>

Latest revision as of 23:47, 6 March 2022

In regards to detection of a venous air embolus, which of the following modalities is most sensitive?

A. Echocardiography

B. Precordial Doppler

C. EKG

D. Right atrial pressure monitor

E. Arterial blood pressure monitor

F. End-tidal nitrogen concentration

G. End-tidal carbon dioxide concentration

Click for Answer

Answer

The answer is B. Doppler is the most sensitive. Echo is the most specific. All others can be used and have signs associated with VAE.